ODIN1400
Up to 4 simultaneous axis TRUE DIGITAL servo-controller.Low cost, highly flexible, PC interface.
We developed this servo-controller in partnership with InsysCorp, Michigan, USA. It is a result of both companies experience and resulted in a cost effective, flexible and easy to use system.
With a Personal Computer and the ATMP program you can make from single sinusoidal test up to multi channel tests. With ICGen®, another Lynx program, you will be able to make tests with random signal systems like in four posts or road simulators.

Characteristics:
- Bump less start and mode change;
- Test and parameter set up save and recovery;
- Highly intuitive human interface;
Data Acquisition (optional):
- One click start;
- Compatible with Lynx's AqDados® and AqDAnalysis®.
Servo-Controller:
- Digital loop operating at 4 KHz;
- 16 bits resolution;
- up to feedback sources per loop;
- manual PID adjust.
Amplitude control (optional)
- Bi-modal PI. Allows mean and amplitude control from multiple inputs. This method allows an easier control for tests with low load and high displacement.

Dual loop/ Installation mode (optional):
- Great for assembling sensitive parts in framed actuators;
- Dual loop technology: inner and outer loop with different feedbacks (e.g., inner loop in force, and outer loop in displacement);
- inner loop limit (assures that the part won't be broken if the operator request an incorrect external loop set point;
Function Generator:
- Frequency range : 0.1 to 200 Hz;
- Waveforms: sinusoidal, rectangular, triangular, double sinusoidal;
- external generator input.
Profiler generator (optional):
- Waveform generation;
- Loops;
- Actions: pump on/off, pressure on/off, wait operator, wait digital input, static set, span set, amplitude control on/off, etc.
Servo-valve driver:
- 2 stage;
- Up to 50 mA current source or +/- 10 V voltage source (configurable);
- Dither adjust from 0 to 25%, frequency from 15 to 1000 Hz.
Hydraulic command :
- Pump on/off with relays: 1A, 24 VDC;
- Status / pump interlock;
- Standard industrial M12 connectors;
- Pressure control: low and high with relays 1A, 24 VDC;
Signal conditioners:
- Configurable by jumpers and software (gain, offset, balance and shunt cal);
- 1 AC/DC conditioner for LVDTs or resistive bridge sensors;
- 2 DC conditioners for resistive bridge sensors;
- On and off line calibration ;
- 2 encoder inputs.
Limits:
- Minimum and maximum values;
- Instantaneous error, amplitude and mean errors;
- Configurable action on limit.
Power supply:
- 90 to 240 VAC, 47 a 63 Hz;
Dimensions (Control Unity)
- High: 87 mm
- Length: 305 mm
- Depth: 268 mm
Dimensions (Channel Unity)
- High: 56 mm
- Length: 305 mm
- Depth: 268 mm
Booklet ODIN1400